CommScope Certified Partner  |  TIA/EIA Compliant  |  Cat6 / Cat6A  |  Lifetime Guarantee Included
Structured Cabling Systems

The Foundation of Everything That Runs on Your Network

TCG designs and installs TIA/EIA-compliant structured cabling systems for enterprise, government, healthcare, and utility facilities across Southeast Michigan — built to perform for decades, and guaranteed for life.

WBE Certified
15+ Years Experience
Lifetime Craftsmanship Guarantee
Michigan-Based Team
24/7 ServicePAK Support

What We Install

Every TCG structured cabling installation is designed to TIA/EIA-568 standards and installed by our own certified technicians — never subcontractors. We deliver full test documentation at closeout.

Cat6 & Cat6A Horizontal Cabling

Properly routed, terminated, and Fluke-certified horizontal cabling runs from the IDF to every workstation, access point, and device. We spec Cat6A for 10G-ready environments and follow proper bend radius and fill ratios on every run.

Telecommunications Room (TR) Buildouts

Patch panels, cable managers, ladder rack, and proper labeling for every TR and IDF. We build rooms that technicians can actually work in — clean, organized, and documented.

Fiber Backbone Cabling

Single-mode and multimode fiber connecting building MDFs to IDFs and core switches to distribution layers. OTDR-tested and verified from end to end.

TIA/EIA Certification Testing

Every horizontal run tested with Fluke DSX series analyzers and verified to channel or permanent link specs. Full test reports delivered in your closeout package.

Data Center & Server Room Cabling

Structured cabling for racks, patch panels, and top-of-rack switching. Clean, labeled, color-coded, and ready for your operations team.

Cable Management & Containment

J-hooks, cable tray, wire managers, velcro bundling, and pathway routing done right. Neat cable management is part of what the lifetime guarantee covers.

Who It's For

TCG installs structured cabling for the facilities where quality and compliance aren't optional.

  • Healthcare — nurse call, network drops, Wi-Fi AP backbone for hospitals and clinical campuses
  • Government & Municipal — courthouses, public safety buildings, city halls
  • Education — K-12 and universities; E-rate eligible structured cabling
  • Enterprise & Commercial — headquarters, distribution centers, corporate campus
  • Utilities — substations, operations centers, field offices
  • Airport & Aviation — DTW CIDA-badged team for airside and secure-area access
Case Study

400-Drop Cabling Refresh — Regional Michigan Healthcare System

An aging Cat5e infrastructure was limiting bandwidth across clinical and administrative wings, with no documentation of existing runs. TCG performed a full cable plant audit, produced as-built drawings, and installed 400 Cat6A runs with new patch panels, cable management, and IDF buildouts — while keeping the facility operational throughout.

Result: Full 10G-capable infrastructure, Fluke-certified test reports on every run, and CommScope 25-year system warranty delivered with closeout package.

Why TCG for Structured Cabling

CommScope Certified — Manufacturer Warranty Included

As a CommScope certified partner, TCG installs cable systems that qualify for the 25-year CommScope end-to-end warranty — which most Michigan cabling contractors cannot offer. That's on top of TCG's own lifetime craftsmanship guarantee.

Lifetime Guarantee + 100% Self-Performing

Every cable run, every termination, every splice our own technicians touch is backed by TCG's lifetime craftsmanship guarantee — included on every installation at no additional cost. No registration, no expiration.

Fluke-Certified Testing on Every Run

We don't assume a cable passes. Every horizontal run is tested with a Fluke DSX analyzer to TIA/EIA channel or permanent link specs. Test results are provided in your closeout package — every run, every result.

Frequently Asked Questions

Cat6 supports 10G speeds up to 55 meters; Cat6A supports 10G for the full 100-meter horizontal run. For new construction or major renovations, TCG recommends Cat6A — it future-proofs your infrastructure for PoE++ devices, higher-density Wi-Fi, and 10G switching without re-cabling later.
For clients who want the 25-year CommScope end-to-end warranty, yes — it requires CommScope components throughout. We also install other manufacturer-specified cable when required by the project spec. We'll tell you upfront what warranty coverage applies.
We plan the work around your operations — phasing runs through different areas, scheduling disruptive work during off-hours, and coordinating with your facilities team to minimize impact. Occupied facility work is something we do routinely for hospitals and government buildings.
Every TCG structured cabling project closes with: as-built documentation, Cert Test Set reports for every run, rack and panel labeling schedules, and written confirmation of the lifetime guarantee. For CommScope-warranted installations, we also provide the manufacturer warranty documentation.
Yes. Structured cabling and fiber infrastructure installed by TCG qualifies under the FCC E-rate program. We work with Michigan school districts through the E-rate documentation process and can help scope the work appropriately for your application.
Take the Next Step

Request a Structured Cabling Quote

Tell us about your facility and we'll connect you with a TCG specialist — most quotes delivered within 48 hours of site assessment.